bluesky.plan_stubs.rd#
- bluesky.plan_stubs.rd(obj: Readable, *, default_value: Any = 0) Generator[Msg, Any, Any][source]#
- Reads a single-value non-triggered object - This is a helper plan to get the scalar value out of a Device (such as an EpicsMotor or a single EpicsSignal). - For devices that implement the Locatable protocol, the location is canonical and is returned without parsing the read keys. - For devices that have more than one read key the following rules are used: - if exactly 1 field is hinted that value is used 
- if no fields are hinted and there is exactly 1 value in the reading that value is used 
- if more than one field is hinted an Exception is raised 
- if no fields are hinted and there is more than one key in the reading an Exception is raised 
 - The devices is not triggered and this plan does not create any Events - Parameters:
- objDevice
- The device to be read 
- default_valueAny
- The value to return when not running in a “live” RunEngine. This come ups when - ret = yield Msg('read', obj) assert ret is None - the plan is passed to list or some other iterator that repeatedly sends None into the plan to advance the generator. 
 
- Returns:
- valAny or None
- The “single” value of the device